Stenting complex aortic coarctation: simulation in a 3D printed model.

Disclaimer:

As a public service to our readership, this article - peer reviewed by the Editors of EuroIntervention - has been published immediately upon acceptance as it was received. The content of this article is the sole responsibility of the authors, and not that of the journal or its publishers. To read the full content of this article, please download the PDF.

Sign in to download the full article

1. IRCCS Policlinico San Donato, ITALY; 2. IRCCS Policlinico San Donato; 3. IRCCS Policlinico San Donato

A 23 years old lady with aortic coarctation was referred for percutaneous treatment. Cardiac CT demonstrated severe coarctation distal to the origin of the left carotid artery (LCA) with hypoplasia of the left subclavian artery. The planned procedure was to implant a covered stent to reduce the risk of aortic dissection or rupture. However, using a covered stent, a risk to occlude the origin of the LCA had to be considered. An innovative approach was planned and tested in a 3D model printed in HeartPrint® Flex material (Materialise,…