20155 results for «»
20155 results
Francesca Ziviello
Rotterdam, Netherlands
Gintautas Bieliauskas
Copenhagen, Denmark
Imaging and physiology-guided PCI without contrast administration in advanced renal failure
11 Apr 2019
In patients with advanced chronic kidney disease who require revascularization, PCI may safely be performed without contrast using imaging and physiological guidance with high procedural success and without complications. Find out more.
Author
Author
Author

Author

André Costa
Lisboa, Portugal
Karsten Vejen
References in coronary rotational atherectomy complications: Rotablator
27 Mar 2019
Consult the below references associated to the clinical research and case reports on rotational atherectomy (RA) complications.

Snare technique
27 Mar 2019
There are several techniques typically employed to retrieve a stuck rotablator burr. The snare can be be attempted but not in first attention.

Mini-STAR as bail-out strategy for percutaneous coronary interventions and complications
27 Mar 2019
The mini-STAR technique is a promising bailout strategy for the management of entrapped burr in the event of complications, achieving a high procedural success rate and low occurrence of procedural adverse events.

Balloon trapping technique - Coronary Rotablator complications
27 Mar 2019
One of some techniques is to use a 2nd wire and to inflate a balloon...

Coronary stuck burr (in or beyond the stenosis): Kokeshi phenomenon
27 Mar 2019
Burr entrapment is a rare and challenging complication of rotablation. Learn what techniques might be used and follow the step-by-step approach to dealing with this complication

Rotablator: stuck burr or blocked rota and shaft fractures
16 May 2019
Coronary embolised device complications
Rotational Atherectomy (RA), a proven and valuable procedure, is a dedicated technique for calcified lesions. Complications related to the Rotablator system have become relatively rare, but they are seen to occur.
This section raises awareness of what complications exist in using the Rotablator system...

Mario Goessl
Minneapolis, United States of America
Entrapped Rotablator retrieved by trapping guide extension catheter technique
27 Mar 2019
Herein we have presented a new retrieval method involving a guide extension catheter combined with a snare, which is used to successfully rescue an entrapped Rotablator.

Coronary rota burr / shaft disconnection
27 Mar 2019
In the case of rota burr or shaft disconnection, the burr has become stuck and when an attempt is made to take it out, the broken shaft could be either within or outside the guiding catheter. Discover how to manage this complication...

Wire under stent struts and rota blocked
27 Mar 2019
Complications using the Rotablator system are increasingly rare, but what if one occurred - for instance, a wire under the stent struts with a blocked rota? Learn how to deal with this complication here…

Battistina Castiglioni
Varese, Italy
Michele Genoni
Zürich, Switzerland
Bilal Hussain
Karachi, Pakistan
Kaushik Patil
Satara, India
Long-term results and durability of the CoreValve transcatheter aortic bioprosthesis: outcomes beyond five years
28 Mar 2019
A study to determine the long-term outcomes of high-risk patients who underwent transcatheter aortic valve implantation with the third-generation CoreValve device, according to the 2017 EAPCI/ESC/EACTS definition of valve durability.
Authors :