Kenji Kawai

Osaka Prefecture, Japan

References in coronary rotational atherectomy complications: Rotablator

27 Mar 2019

Consult the below references associated to the clinical research and case reports on rotational atherectomy (RA) complications.

Snare technique

27 Mar 2019

There are several techniques typically employed to retrieve a stuck rotablator burr. The snare can be be attempted but not in first attention.

Snare technique

Mini-STAR as bail-out strategy for percutaneous coronary interventions and complications

27 Mar 2019

The mini-STAR technique is a promising bailout strategy for the management of entrapped burr in the event of complications, achieving a high procedural success rate and low occurrence of procedural adverse events.

Balloon trapping technique - Coronary Rotablator complications

27 Mar 2019

One of some techniques is to use a 2nd wire and to inflate a balloon...

Coronary stuck burr (in or beyond the stenosis): Kokeshi phenomenon

27 Mar 2019

Burr entrapment is a rare and challenging complication of rotablation. Learn what techniques might be used and follow the step-by-step approach to dealing with this complication

Stuck burr

AICT-AsiaPCR 2019 Sponsored programme

You can now discover the sessions lined up with support from AICT-AsiaPCR's valued Industry Partners
Sponsored programme at AICT-AsiaPCR 2019

Rotablator: stuck burr or blocked rota and shaft fractures

16 May 2019

Coronary embolised device complications

Rotational Atherectomy (RA), a proven and valuable procedure, is a dedicated technique for calcified lesions. Complications related to the Rotablator system have become relatively rare, but they are seen to occur.

This section raises awareness of what complications exist in using the Rotablator system...

Rotablator

Mario Goessl

Minneapolis, United States of America

Entrapped Rotablator retrieved by trapping guide extension catheter technique

27 Mar 2019

Herein we have presented a new retrieval method involving a guide extension catheter combined with a snare, which is used to successfully rescue an entrapped Rotablator.

Coronary rota burr / shaft disconnection

27 Mar 2019

In the case of rota burr or shaft disconnection, the burr has become stuck and when an attempt is made to take it out, the broken shaft could be either within or outside the guiding catheter. Discover how to manage this complication...

Rota burr

Wire under stent struts and rota blocked

27 Mar 2019

Complications using the Rotablator system are increasingly rare, but what if one occurred - for instance, a wire under the stent struts with a blocked rota? Learn how to deal with this complication here…

Wire under stent struts and rota blocked

Battistina Castiglioni

Varese, Italy

Michele Genoni

Zürich, Switzerland

Bilal Hussain

Karachi, Pakistan

Kaushik Patil

Satara, India

Magdalena Dobrolinska

Katowice, Poland

Tan Kokleng

Federal Territory of Kuala Lumpur, Malaysia

Kathryn Kuan

Dublin, Ireland

Claudio Larosa

Andria, Italy

Didn’t find what you were looking for?