27 Nov 2022
Ensuring optimal TAVI outcomes - LIVE case
Commissural alignment in a young patient with a small annulus and coronary artery disease (CAD)
Operators:
O. De Backer, L. Sondergaard
Procedural Analyst:
J. Khan
Summary
A 75-year-old female with diabetes and history of ischemic stroke 5 years ago presents a symptomatic severe aortic valve stenosis in a small annulus.
After pre-dilatation (18 mm balloon), the operators implant an Acurate neo2 23 mm with a sentinel cerebral embolic protection device. Watch them perform a commissural alignment.
LIVE case from Rigshospitalet Copenhagen University Hospital, Denmark
Navigate the video by moving your mouse over the chapter icon in the toolbar

Key moments
- 03:19 - 06:58 - Imaging analysis
- 27:16 - 30:38 - Commissural alignment
- 30:38 - 35:56 - Acurate neo2 deployment
- 53:43 - 57:26 - Procedural analysis
Keywords: Acurate neo2, small annulus, sentinel, commissural alignment