17 Feb 2024
Achieving the optimal outcome using the latest self-expandable TAVI - LIVE case
Deployment of a self-expandable valve with 3 markers under cusp overlap view
Operators:
H. Kawashima, Y. Watanabe
Procedural Analyst:
T. Sakamoto
Summary
An 86-year-old woman presented severe symptomatic aortic stenosis and coronary artery disease with a preserved LV function. The operators performed a PCI of the RCA ostium one month ago. The CT showed a small femoral access (diameter: 5.3 to 4.9 mm).
After a predilatation with a 20 mm Inoue balloon without stimulation, the team implanted an Evolut FX 29mm under stimulation under a cusp overlap view.
LIVE Case from Teikyo University Hospital - Tokyo, Japan
Navigate the video by moving your mouse over the chapter icon in the toolbar

Key moments
- 30:36-33:00 - 1 proglide preclosing
- 39:27-40:00 - Predilatation with the Inoue balloon
- 43:29-53:23 - Deployment of the valve
Keywords: TAVI, Evolut FX, predilatation, preclosing