Redo TAVI with pre and post dilatation - LIVE Case

Procedural Analyst: N. Piazza
SHOW MORE

Summary

Watch this live case followed by a live in a box case, regarding a 93-year-old woman with hypertension, chronic bronchitis, and a history of TAVI with a Sapien 3 23 mm (2016) who presented with symptomatic severe aortic stenosis and mildly reduced LV function (50%). An Evolut FX 26 mm valve was implanted with pre- and post-dilatation, followed by echocardiographic, angiographic, and hemodynamic assessment.

Live in a box case: An 85-year-old woman with a history of TAVI for bicuspid aortic valve disease (2015) presented with symptomatic severe aortic stenosis. A Sapien 3 23 mm valve was implanted with post-dilatation, and vascular closure was achieved using a MANTA device.

LIVE Educational Case from Hospital Álvaro Cunqueiro - Vigo, Spain

Navigate the video by moving your mouse over the chapter icon in the toolbar

Chapters on Vimeo

Key moments

  • 25:00–28:04 – Predilatation
  • 56:20–1:00:47 – Post-dilatation
  • 29:44–32:17 – Valve crossing
  • 35:00–46:48 – Valve implantation

Keywords: Redo TAVI, Sapien 3, Evolut FX, predilation, post dilatation, landerquist, manta

Presentations available when logged in:

  • Patient presentation and imaging analysis
  • Operator strategy and device overview
  • Recorded Case from Upper Silesian Medical Center - Katowice, Poland