Double guide catheters technique

Complications

Consult the additional resource on the double guide catheters technique.

Coronary perforation Type III - Double guide catheters technique

The below schematic diagram shows the step-by-step double guide catheters technique.

(A) Balloon used in the angioplasty inflated at low pressure (4 ATM) at the perforation site. (B) Careful withdrawal of the first guide catheter outside the ostium and catheterization of the coronary ostium with the second guide catheter. (C and D) Advancement of the second guide catheter, crossing the perforation site with quick balloon deflation, allowing its passage. (E) Coated stent advancing over the second guide catheter. (F) Rapid deflation manoeuvre, balloon withdrawal and coated stent implantation at the perforation site.

Double guide catheters technique

Reference

  1. Tratamento com a Técnica de Duplo Cateter-Guia  de Perfuração Coronária Tipo III
    (Treatment with the Double Guiding Catheter Technique for Type III Coronary Perforation)
    Evandro Martins Filho, Tarcísio Campostrini Borghi Jr., Marcelo Aguilar Puzzi, Ricardo Costa, Dimytri Siqueira, Rodolfo Staico, Alexandre Abizaid
    Rev bras Cardiol Invasiva 2013; 21:401-5 Vol. 21

Return to Link 2

Disclaimer

This case report does not reflect the opinion of PCR or PCRonline, nor does it engage their responsibility.