Link 2: How to implant covered stent

Complications: Coronary perforation

The choice and type of covered stents depends on the conditionsprocedural circumstances. Before implanting a covered stent one needs to check the compatibility of the device with the guiding catheter.

6Fr guiding catheter:

  • If balloon is inflated at perforation site
    • Insert a second guiding catheter (second arterial access, consider femoral ≥ 7Fr), please consult Double guide catheters technique
    • Parallel guide wire
    • Deploy covered stent through second guiding catheter

7Fr / 8Fr guiding catheter:

  • If balloon is inflated at perforation site
    • Insert a second guide wire in the same guiding catheter
    • Implant covered stent
  • If balloon is out of the guiding catheter
    • Insert a covered stent directly

Return to main page

Disclaimer